Agilent 16517A, 16518A Synchronous State Logic Analyzer

Posted by

Read Online or Download Agilent 16517A, 16518A Synchronous State Logic Analyzer (service) PDF

Similar logic books

Advances in Proof-Theoretic Semantics

This quantity is the 1st ever assortment dedicated to the sector of proof-theoretic semantics. Contributions tackle subject matters together with the systematics of advent and removing ideas and proofs of normalization, the categorial characterization of deductions, the relation among Heyting's and Gentzen's methods to which means, knowability paradoxes, proof-theoretic foundations of set conception, Dummett's justification of logical legislation, Kreisel's conception of buildings, paradoxical reasoning, and the defence of version thought.

The Soft Budget Constraint — The Emergence, Persistence and Logic of an Institution

This can be a tale of the delicate finances constraint. It seeks a solution to a paradox: the superiority of the delicate price range constraint despite the great inefficiencies that it offers upward push to, and its endurance regardless of reform of the method of which it really is a vital part. the tale goals at expanding our figuring out of why the phenomenon exists.

Additional resources for Agilent 16517A, 16518A Synchronous State Logic Analyzer (service)

Sample text

000:1. c Disconnect the BNC coax cable from the calibration pod and connect the cable to the oscilloscope Channel 2 input. Select Autoscale. d Press the Display key. Select # of averages 16. e Measure the frequency. Push the blue shift key, then push Frequency, then push 2. 125 MHz. Record the value in the performance test record. f Measure the rise time. Push the blue shift key, then push Rise, then push 2. 35 ns. Record the values in the performance test record. 3–6 To perform the self-tests The self tests verify the correct operation of the module.

C Solder the center of the BNC connector to the center pin of one row on the Berg strip. d Solder the ground tab of the BNC connector to the center pin of the other row on the Berg strip. 3–4 To test the calibration signal Although the calibration signal test does not test a logic analyzer specification, it does verify the accuracy of the calibration signal. The calibration signal, used for the skew adjustment, is verified using a general purpose 500 MHz oscilloscope. The frequency, rise time, and DC offset voltage are measured and recorded in the performance test record.

C Touch Done. 2 Touch Trigger, then select Format. The activity indicators should show activity on the master card pod 1 data channels and on the master card pod 1 clock channel. 400 ns. 3 Configure the sample offset to +400 ps. a Select the Set Sample Offset field. Use the knob to set the sample offset value to 400 ps as shown in the Sample Offset field. b Touch the Sample Offset Mode Coarse field. The field should toggle to Set Offset Mode Fine. Use the knob to set the sample offset value to 350 ps.

Download PDF sample